# Hercules Card Reader Device Commands
|
|
|
|
This document contains the Hercules console commands used to manage the card reader device (00C/3505).
|
|
|
|
## View Device Status
|
|
|
|
```
|
|
devlist 00c
|
|
```
|
|
|
|
**Example Output:**
|
|
```
|
|
HHC02279I 0:000C 3505 3505 sockdev ascii trunc eof IO[2]
|
|
HHC02279I (no one currently connected)
|
|
```
|
|
|
|
**Key Information:**
|
|
- `IO[n]` - Shows the I/O state number
|
|
- `(no one currently connected)` - Socket is free
|
|
- `(client IP (<unknown>) connected)` - Socket is in use
|
|
|
|
## Reset Card Reader (When Stuck)
|
|
|
|
### Method 1: Detach and Reattach (Recommended)
|
|
|
|
```
|
|
detach 00c
|
|
attach 00c 3505 3505 sockdev ascii trunc eof
|
|
```
|
|
|
|
This completely removes and recreates the device, clearing any stuck connections.
|
|
|
|
### Method 2: Devinit (May Not Work if Socket is Wedged)
|
|
|
|
```
|
|
devinit 00c 3505 3505 sockdev ascii trunc eof
|
|
```
|
|
|
|
**Note:** `devinit` may fail with "Address already in use" if the socket is stuck. Use Method 1 instead.
|
|
|
|
## Common Issues
|
|
|
|
### Device Stuck in "IO[n] open" State
|
|
|
|
**Symptoms:**
|
|
- `devlist 00c` shows `IO[5] open` or similar
|
|
- Client shown as connected even after jobs complete
|
|
- New connections rejected with "device busy or interrupt pending"
|
|
|
|
**Solution:**
|
|
```
|
|
detach 00c
|
|
attach 00c 3505 3505 sockdev ascii trunc eof
|
|
```
|
|
|
|
### Connection Refused from Workflow
|
|
|
|
**Symptoms:**
|
|
- Workflow logs show: `Connection refused` from netcat
|
|
- Device shows: `localhost:3505` in devlist
|
|
|
|
**Problem:** Device bound to localhost only, not accepting external connections.
|
|
|
|
**Solution:**
|
|
Use port number only (binds to all interfaces):
|
|
```
|
|
detach 00c
|
|
attach 00c 3505 3505 sockdev ascii trunc eof
|
|
```
|
|
|
|
**DO NOT USE:**
|
|
```
|
|
attach 00c 3505 localhost:3505 sockdev ascii trunc eof # Wrong - localhost only
|
|
attach 00c 3505 0.0.0.0:3505 sockdev ascii trunc eof # Also fails on some systems
|
|
```
|
|
|
|
## Device Configuration for Workflow
|
|
|
|
For the Gitea workflow to connect successfully, the card reader must be configured to accept connections from any interface:
|
|
|
|
```
|
|
attach 00c 3505 3505 sockdev ascii trunc eof
|
|
```
|
|
|
|
Verify with:
|
|
```
|
|
devlist 00c
|
|
```
|
|
|
|
Should show:
|
|
```
|
|
HHC02279I 0:000C 3505 3505 sockdev ascii trunc eof IO[n]
|
|
```
|
|
|
|
**Not:**
|
|
```
|
|
HHC02279I 0:000C 3505 localhost:3505 sockdev ascii trunc eof IO[n] # Wrong
|
|
```
|
|
|
|
## Troubleshooting Workflow Socket Issues
|
|
|
|
If workflows are failing with socket errors:
|
|
|
|
1. **Check device status:**
|
|
```
|
|
devlist 00c
|
|
```
|
|
|
|
2. **Look for stuck connections:**
|
|
- `IO[5] open` with client connected = stuck
|
|
|
|
3. **Reset the device:**
|
|
```
|
|
detach 00c
|
|
attach 00c 3505 3505 sockdev ascii trunc eof
|
|
```
|
|
|
|
4. **Verify it's ready:**
|
|
```
|
|
devlist 00c
|
|
```
|
|
Should show `(no one currently connected)`
|
|
|
|
## Prevention
|
|
|
|
The `submit_job.py` script now includes a 10-second delay between submissions to prevent socket conflicts:
|
|
- Upload job submits
|
|
- Wait 10 seconds for JES to process
|
|
- Compile job submits
|
|
|
|
This gives Hercules time to fully close the socket between connections.
|